Energy Efficient Rooflights

Two numbers decide whether a rooflight adds to a heating bill or quietly reduces one: the U-value, which is how fast heat leaves through it in winter, and the g-value, which is how much solar heat comes in through it in summer.

Get a quote Read the technical detail

  • 15 years in Gloucestershire
  • 10-year workmanship guarantee
  • Building Control notification handled
  • The roof is never left open overnight

Tell us about the roof

We will come and look at it, and tell you honestly what it needs.

Why installations fail

The unit is the small half of the job.

A rooflight specified to a good U-value and then installed into a cold perimeter does not deliver the figure on the certificate. Four things decide what the room actually feels, and only one of them is the glass.

  1. The glazing specification. U-value and g-value chosen for the aspect rather than from a catalogue.
  2. The kerb insulation. Through its full depth, so the timber does not run cold from top to bottom.
  3. The vapour control layer. Taped to the frame, not trimmed short and left loose.
  4. Ventilation. A route out for the moisture the room makes, or the glass collects it.

That is what the ten-year workmanship guarantee is written against.

A vertical window collecting light from part of the sky beside a rooflight collecting light from the whole sky dome. The whole dome of sky Vertical window Rooflight
A rooflight faces the whole dome of sky and is shaded by neither the fence nor the neighbouring house, which is why it delivers several times what a vertical window of the same area does. This is the reason a north facing room can be transformed by glass in the roof.
How it runs

Two figures, and no surprises between them.

  1. Send photographs A few pictures of the roof and the room, and rough measurements. An indicative range comes back by email.
  2. The survey Forty minutes on site. Rafter centres, pitch off a digital level, the deck, the fall, and how a scaffold reaches the elevation.
  3. A fixed price Written against what was measured, not against the drawing. It does not move unless you change what you asked for.
  4. The installation Scaffold, opening, kerb, unit, weathering, reveal and making good. The roof is never left open overnight.
  5. Notification and guarantee The Building Control notification is submitted and closed out as part of the job, and the workmanship carries ten years.
Asked before every job

The questions that come up first.

What U-value should a rooflight have?

Ask for a whole-unit figure of 1.2 to 1.4 W/m2K on a manufactured roof window, and 1.0 to 1.3 on a good made-to-size flat rooflight. Those are the numbers a current product reaches without anything exotic, and they are the numbers worth writing on an order. Building Regulations set a limiting standard rather than a target: 1.4 for a replacement…

The full answer

Will a rooflight make my room too hot?

It might, and whether it does comes down to four things: which way the slope faces, how steeply it is pitched, how much glass there is relative to the floor below, and what the room already does to itself. Get all four wrong and a loft bedroom in a Gloucester semi will be unusable between two and seven on a…

The full answer

What causes condensation on a rooflight?

Condensation on a rooflight is warm indoor air meeting cold glass. Three conditions have to line up: moisture in the air, a surface below the temperature at which that air gives up its water, and not enough air movement to carry the moisture away before it lands. Overhead glass satisfies the second condition better than anything else in the house,…

The full answer

Are rooflights bad for insulation?

Per square metre, yes. A current rooflight loses somewhere between eight and ten times as much heat as the insulated roof it sits in, and no glazing product will ever close that gap. Per room, and over a year, the answer is much less clear cut, because the same hole delivers daylight that displaces electric lighting and free solar heat…

The full answer

Is triple glazing worth it in a rooflight?

Sometimes, and the deciding factor is usually not the U-value. A triple unit takes a good rooflight from about 1.2 W/m2K to about 0.85, which on a typical roof window saves in the order of forty kilowatt hours over a Gloucestershire heating season. That is worth having and it is not, on its own, a reason to buy one. The…

The full answer

What is a g-value?

A g-value is the fraction of the sun's energy falling on a piece of glass that ends up as heat inside the room. It is written as a decimal between 0 and 1. Glass with a g-value of 0.6 passes 60 per cent of the arriving solar energy through; glass at 0.27 passes 27 per cent. It is also called…

The full answer

Do rooflights lose more heat than windows?

Yes, and the gap is bigger than the datasheets suggest. The same sealed unit, the same coating and the same gas fill will lose roughly 10 to 20 per cent more heat lying in a roof than standing in a wall, and against a real night sky the difference in how it feels is larger again. Three separate mechanisms cause…

The full answer

How do you stop a rooflight overheating?

Stop the energy on the outside of the glass, then get rid of what still arrives. Those two moves, in that order, do almost all of the work, and everything else is refinement. Solar control glass and external shading intercept the heat before it is committed to the room. Ventilation, thermal mass and reducing what the room generates on its…

The full answer

The technical detail

The glass is the easy half, the perimeter is the rest.

Two numbers decide whether a rooflight adds to a heating bill or quietly reduces one: the U-value, which is how fast heat leaves through it in winter, and the g-value, which is how much solar heat comes in through it in summer. Everything else on a datasheet is downstream of those two. What almost nobody explains is that both figures are measured under conditions that do not match a roof, that the same product can legitimately be quoted with two different U-values depending on which plane it was declared in, and that the installed performance of a well specified unit is routinely thrown away by 40mm of missing insulation at the head of the reveal. This page is the thermal half of the trade, written for Gloucestershire roofs, and it sits alongside the rest of the rooflight and skylight services as the technical background to specifying a unit rather than a separate product.

27 sections 33 minute read

The two numbers that decide whether a rooflight saves energy

The U-value is measured in watts per square metre per kelvin, W/m2K, and it counts how much heat passes through one square metre of the finished unit for every degree of difference between the room and the outside air. Lower is better. A single-glazed Victorian rooflight sits somewhere near 5.0. A double-glazed unit from the 1990s runs 2.8 to 3.0. A current manufactured roof window is 1.0 to 1.4, and a triple-glazed one can reach 0.6 to 0.8.

The g-value, sometimes written as the solar factor, is a fraction between zero and one. It is the proportion of the solar energy striking the glass that ends up as heat in the room, counting both the radiation that passes straight through and the part absorbed by the glass and then re-radiated inwards. Clear double glazing is around 0.6 to 0.7. A solar control unit is 0.25 to 0.35.

The two numbers pull in opposite directions for part of the year. A low g-value keeps a loft room usable in July and gives up some free winter heat in exchange. A high g-value collects that winter heat and makes the same room unbearable by four in the afternoon in August. Which trade is correct depends on the orientation of the slope, the room underneath, and how much glass is going in, and that judgement is made at survey rather than on a website.

Whole-unit U-values, centre-pane figures, and how to read a datasheet

A vertical window collecting light from part of the sky beside a rooflight collecting light from the whole sky dome. The whole dome of sky Vertical window Rooflight
A rooflight faces the whole dome of sky and is shaded by neither the fence nor the neighbouring house, which is why it delivers several times what a vertical window of the same area does. This is the reason a north facing room can be transformed by glass in the roof.

The most common way a homeowner is misled is by a centre-pane figure quoted as though it described the unit. Centre-pane, written Ug in the literature and usually just labelled glass U-value, measures the middle of the glazing away from the edges. It ignores the spacer bar, the edge seal and the frame, which are the three worst-performing parts of any glazed unit.

The number that matters is the whole-unit value, Uw for a roof window or Url for a made-to-size rooflight. It is an area-weighted combination of the glass, the frame and the linear heat loss along the perimeter of the glass where it meets the frame. On a small unit the frame is a large fraction of the total area, so the whole-unit figure drifts a long way from the glass figure. A 550 by 780mm window and a 1340 by 1400mm window with identical glass and identical frames will not have the same whole-unit U-value, and the small one will be worse.

So when two products are being compared, the only fair comparison is whole-unit against whole-unit, at a stated size, declared to the same standard. Ask which figure is being quoted. A supplier who cannot say is quoting the glass.

A centre-pane figure and a whole-unit figure for the same product can differ by more than 0.4 W/m2K, which is the whole of the improvement between two glazing generations.

The vertical plane convention, and why two U-values are not always comparable

This is the part of rooflight specification that catches out architects, never mind homeowners. Glazing U-values are calculated and tested with the specimen standing vertical, because that is how the standards were written for windows. A rooflight does not stand vertical. It lies at somewhere between five and forty-five degrees, and at that angle it loses more heat than the same unit would upright.

The industry therefore declares rooflight U-values one of two ways: in the vertical plane, which is the standard laboratory condition, or in the horizontal plane, which is closer to how a flat roof unit is actually installed. The horizontal figure is always the worse of the two. The same product can honestly be advertised at, say, 1.3 in the vertical plane and 1.6 in the horizontal, and both numbers are true statements about different test conditions.

That is also why the Building Regulations quote a limiting standard for rooflights measured in the vertical plane. It puts a kerb-mounted flat roof unit on the same footing as a window so the two can be compared, and it means the regulatory figure is not a prediction of installed performance. When a specification is being pinned down for a flat roof rooflight, the question to ask the manufacturer is which plane the declared value refers to, and then to ask for the other one.

Pitch changes the number: convection inside the cavity at 15, 30 and 45 degrees

The physics behind that penalty is worth understanding, because it decides how much triple glazing is worth on a shallow roof. Inside a sealed unit, the gap between the panes is filled with a gas that is a poor conductor. Heat crosses it three ways: conduction through the gas, radiation between the two glass surfaces, and convection, which is the gas circulating.

In a vertical unit the warm inner pane and the cold outer pane are side by side, so the gas rises up one face and sinks down the other in a slow, stable loop that moves relatively little heat. Tilt the unit and that loop changes character. Lay it near horizontal and the warm surface is at the bottom and the cold surface at the top, which is the classic unstable arrangement: the gas rises in plumes, dumps its heat at the cold pane and falls again, and convective transfer across the cavity increases sharply.

The practical consequence is that a sealed unit optimised for vertical use is not optimised for a roof. A cavity of 15 to 16mm is close to ideal for argon in a vertical window. In a shallow rooflight the same cavity convects harder, and a slightly narrower gap, or a third pane splitting the cavity in two, does more good than the vertical numbers suggest. Below about 10 degrees the effect is at its worst, which is exactly the pitch of most flat roof units and most of the shallow upper slopes behind Cheltenham’s parapets.

Gas fill, cavity width and the warm-edge spacer

Daylight from above falling across an interior wall

Air conducts heat at roughly 0.025 W/mK. Argon is about 0.017, krypton about 0.0094. Swapping air for argon is close to free at manufacture and is standard on every current unit worth fitting. Krypton costs considerably more and is worth it mainly where the cavity has to be narrow, which is why it appears in slim triple-glazed units and heritage-profile glass rather than in a standard roof window.

Cavity width has an optimum rather than a direction. Too narrow and conduction across the gas dominates. Too wide and convection takes over. For argon in a vertical unit the sweet spot is around 15 to 16mm; for krypton it is nearer 10 to 12mm because the gas is denser and starts convecting sooner. A 20mm argon cavity is worse than a 16mm one, which surprises people who assume thicker is better.

The spacer bar around the perimeter is the other half of the story. A traditional aluminium spacer is a strip of metal linking the cold outer pane directly to the warm inner one, which is a thermal bridge running the entire perimeter of the glass. A warm-edge spacer, made from stainless steel foil, a polymer, or a composite, cuts that bridge. It improves the whole-unit U-value by roughly 0.1 W/m2K on a typical size, and more usefully it raises the glass surface temperature at the edge by several degrees. That is the strip where condensation forms first, so warm edge is a condensation measure as much as a heat-loss measure.

  • 16mm
  • 12mm
  • 20mm

Triple glazing overhead, and when the extra weight earns its place

Triple glazing on a roof is a genuine improvement and it is not automatically the right answer. A good triple unit with two low-emissivity coatings and argon reaches a centre-pane value near 0.6 and a whole-unit value of 0.8 to 1.0 in a manufactured roof window. Against a double unit at 1.2 to 1.4 that is a real reduction in heat loss from the coldest surface in the room.

Three things push back. The first is weight: a third pane adds roughly 10 to 12 kilograms per square metre, which changes the manual handling on a scaffold, the load on the trimmer, and the effort needed to open a large top-hung sash by hand. On a steep Forest of Dean roof where the top of the frame is already high, an operating rod on a heavier sash becomes tiring, and an electrically operated unit starts to look sensible. That option is set out on the electric rooflight installation page.

The second is light. Every pane and every coating takes a slice of visible light. A clear double unit transmits around 78 to 82 per cent; a triple with two coatings is nearer 65 to 70. In a north-facing Stroud valley cottage with one small opening, that difference is visible in the room.

The third is that the unit stops being the weakest element. Once a roof window is at 0.8, the reveal, the perimeter seal and the surrounding roof insulation dominate the heat loss around that opening. Spending on the glass while leaving a cold bridge at the head of the reveal is money going in the wrong order.

Frame material and the conduction path around the edge of the glass

The frame is usually a quarter to a third of the area of a domestic rooflight, and it is the part with the most variation between products.

Frame construction Approximate frame U-value What it does well What it costs you
Laminated pine, factory finished, timber conductivity around 0.13 W/mK 1.3 to 1.6 Warm frame, warm internal surface, straightforward to fix and flash with a matched kit Needs a maintained finish, and the sight line is thicker than an aluminium unit
Timber core with a polyurethane skin, foam conductivity around 0.03 W/mK 1.1 to 1.4 Best thermal performance of the manufactured window frames, and unaffected by humidity, so it suits bathrooms and kitchens Limited to the manufacturers’ standard sizes and finishes
Thermally broken aluminium with a polyamide break of 24 to 34mm 1.6 to 2.2 Very slim sight lines, large spans, and made-to-size widths for a kerb The break has to be continuous at the corners, and a poorly broken frame is a cold ring around the glass
Aluminium with no thermal break Above 5.0 Nothing that matters on a heated room Runs with condensation every cold morning and drips onto the cill
PVC-U, conductivity around 0.17 W/mK, multi-chambered 1.2 to 1.8 Warm, and undisturbed by moisture Thicker sections for the same strength, and the profile reads as modern on an older roof
Cast or pressed steel conservation frame, steel conductivity around 50 W/mK 2.0 to 3.0 The only profile a conservation officer will usually accept on a stone roof A slim, highly conductive frame plus a central glazing bar, both of which are thermal bridges

The trade hidden in that table is that a slim frame and a warm frame are opposing goals. Insulation needs thickness. A 40mm aluminium sight line has almost nowhere to put a polyamide break, whereas an 80mm timber section is insulating along its whole depth. Slim frames give a higher glass fraction, which helps the area-weighted average, and a worse frame value, which hurts it. Which wins depends on the size of the unit.

Glass build-ups against what each one actually does

Build-up Centre-pane U-value g-value Light transmission Where it belongs
Single glazing, original heritage rooflight Around 5.4 0.85 0.90 Only where a listing genuinely requires the original glass retained
Clear double, air filled, no coating, 1980s specification 2.8 to 3.0 0.75 0.81 What is usually coming out of a roof rather than going into one
Double, argon, one soft-coat low-E on the inner pane 1.1 to 1.2 0.55 to 0.63 0.78 to 0.80 The sensible default for a north or east facing slope
Double, argon, low-E plus solar control on the outer pane 1.0 to 1.2 0.25 to 0.35 0.50 to 0.65 South and west facing slopes, and any loft bedroom
Triple, argon, two low-E coatings 0.6 to 0.7 0.45 to 0.52 0.65 to 0.70 Rooms heated to a steady temperature, and shallow pitches where convection is worst
Triple, krypton, slim 10mm cavities 0.6 to 0.8 0.45 to 0.50 0.63 to 0.68 Where the frame rebate cannot take a wide unit, including conservation profiles
Laminated inner pane, 6.8mm or 8.8mm, over any of the above No meaningful change Slight reduction Slight reduction Mandatory over habitable space, a stairwell or a bath, and it cuts rain noise on a shallow unit
Self-cleaning outer coating over any of the above No change Marginal reduction Marginal reduction Units above a stairwell or a two-storey space where cleaning is unrealistic

The figures move slightly between manufacturers and between sizes, and the pattern does not. Solar control buys a large reduction in summer gain at the price of some daylight. Triple glazing buys a large reduction in winter loss at the price of some daylight and some weight. Nothing in glazing is free.

Solar altitude at Gloucester: 14.7 degrees in December, 61.6 in June

Gloucester sits at about 51.9 degrees north. At noon on the winter solstice the sun reaches an altitude of roughly 14.7 degrees above the horizon. At noon on the summer solstice it reaches roughly 61.6 degrees. That swing of nearly 47 degrees is the single most important fact in specifying glass for a roof, and it is why a rooflight behaves nothing like a window in a wall.

Take a south-facing slope at 30 degrees, which describes a great many concrete-tiled rear slopes in Longlevens, Hucclecote and Quedgeley. A surface at 30 degrees has its perpendicular pointing at 60 degrees altitude. In June the midday sun sits at 61.6 degrees, which is within two degrees of perpendicular: the glass is very nearly square-on to the strongest sun of the year, collecting close to the full irradiance available, which on a clear June day is around 850 to 900 watts per square metre before the glass takes its cut. In December the same slope meets the sun at 45 degrees off perpendicular and collects about 70 per cent of what falls, from a much weaker sun, for barely eight hours of daylight against nearly seventeen in June.

A near-horizontal unit is more lopsided still. At five degrees of pitch the glass is 23 degrees off perpendicular in June and 70 degrees off in December, so it takes roughly three times the midday irradiance in summer that it does in winter. Overhead glazing is a summer collector. Any argument that a rooflight will pay for itself in winter solar gain has the geometry backwards.

  • 51.9°
  • 14.7°
  • 61.6°
  • 47°

Orientation, and why a west-facing loft is the hard case

The compass direction of the slope changes the specification more than any other single input, and on a lot of Gloucestershire houses it is not a choice.

A north-facing slope takes no direct sun at all for most of the year and delivers steady, even diffuse light with no glare and almost no solar gain. It is the easy case: pick the lowest U-value you are willing to pay for, take the highest light transmission available, and skip solar control entirely.

South is manageable because the peak arrives at midday when the room is usually empty and the outside temperature has not yet peaked, and because the high summer sun angle means a modest external shade cuts a lot of it.

West is the difficult one. The sun swings round to the west-north-west by late afternoon in July, dropping to a lower altitude as it goes, and a west-facing slope is presented more squarely to it exactly as the air temperature reaches its daily maximum around four to five in the afternoon. The room has already been warming all day. A loft conversion has plasterboard and insulation rather than masonry, so there is almost no thermal mass to absorb the peak, and the heat arrives at the hour the room is most likely to be occupied. A west-facing loft bedroom with clear double glazing overhead is the classic unusable summer room, and solar control glass plus external shading is not an upgrade there, it is the specification.

East warms a room hard between seven and ten in the morning and then releases it, which is tolerable in a bedroom and unhelpful in a home office.

Where the orientation is fixed by the building, and it usually is, the answer moves to the glass and the shading. Gloucester’s Victorian terraces are a good example: a two-storey rear addition has one lean-to slope facing whichever way the back of the house faces, the kitchen is underneath it, and there is no alternative elevation. The roof window installation page covers how position on that slope is worked out.

Solar control coatings, and the trade against daylight

A solar control coating is a stack of metal-oxide layers, usually including a very thin silver layer, sputtered onto the outer pane in a vacuum. It reflects a large part of the near-infrared while passing most of the visible spectrum. That selectivity is the whole point: a sheet of tinted glass cuts heat and light in roughly equal measure, while a modern coating cuts far more heat than light.

The measure of how well it does that is the selectivity ratio, light transmission divided by g-value. Clear double glazing is around 1.2. A good solar control unit reaches 1.8 to 2.0, which means it is passing nearly twice as much light as heat, proportionally. When two solar control products are being compared, that ratio is a more honest guide than the g-value alone, because a low g-value achieved by making the glass dark is not an achievement.

The visible penalty is a faint tint, usually a very slight green or neutral grey, most noticeable when a coated unit sits next to an uncoated one on the same elevation. That is a reason to specify all the units on a roof to the same build-up when several are going in on one visit, rather than upgrading one and leaving the rest.

A flush glazed rooflight set into a flat roof
A flush glazed rooflight set into a flat roof

Shading that works, and shading that only looks like it does

Glass specification sets the ceiling on solar gain. Shading is what controls it day to day, and there is an order of effectiveness that most homeowners have backwards.

Shading Roughly how much solar heat it stops Why Practical notes
External awning blind in mesh fabric, fitted above the glass Around 70 to 80 per cent Intercepts the radiation before it reaches the glass, so the absorbed heat is released to outside air Manual crank or solar-powered motor, retracts for winter, sees daylight through the mesh so the room is shaded rather than dark
External roller shutter Above 90 per cent Blocks radiation entirely and adds an insulating air layer at night Darkens the room completely, and needs power and a control
Solar control glass Around 50 to 65 per cent Reflects near-infrared at the outer surface, permanently and with nothing to operate Works when nobody is home, cannot be turned off in February
Internal pleated or honeycomb blind Around 25 to 40 per cent The heat is already inside the glass, so most of what the fabric absorbs still ends up in the room Useful for glare and for a small night-time insulating benefit, weak on heat
Internal blackout blind in a side channel Around 30 to 45 per cent Same limitation, slightly better because the reflective backing returns some radiation through the glass Traps hot air between fabric and glass, so the cavity needs to vent at the top
Nothing, relying on opening the window Very little during the day Ventilation removes air that is already hot, it does not stop the radiation arriving Genuinely effective overnight, when outside air is cooler than the room

The pattern is consistent: shading outside the glass is two to three times as effective as shading inside it, for the simple reason that heat stopped outside stays outside. An external awning is the single most useful addition to a south or west facing rooflight, and it is far cheaper to fit at installation, while the scaffold is standing, than as a separate visit later.

Overheating, and the standard new homes are designed against

Since 2022 new residential buildings in England have had to be assessed for overheating risk under a dedicated part of the Building Regulations, which limits how much glazing can face east, south and west without shading, and requires a demonstrable route for hot air to leave. That requirement applies to new dwellings rather than to a rooflight going into an existing house, so it is context rather than a rule you have to satisfy.

The physics does not care about the scope of the regulation. A loft room is the hottest room in any house before a single square metre of glass is added, because heat rises, because the roof is the surface with the largest solar exposure, and because a rafter-line insulation build-up has little thermal mass. Add overhead glazing facing south-west and the room can run ten degrees above the rest of the house on a July afternoon.

The approach that works is the same one the regulation uses. Limit the glazed area to what the daylight actually needs rather than the maximum that fits. Put the solar control in the glass. Add external shading on the exposed slopes. And design a ventilation route that lets hot air out at high level and draws cooler air in low down, which on a loft conversion usually means an opening rooflight at the top of the stairs working with a window in the room below. A single opening at high level with no low-level inlet moves very little air.

Thermal bridging at the reveal: the heat loss nobody puts on a quote

A whole-unit U-value describes the unit. It says nothing about the junction between the unit and the roof, and that junction has its own heat loss, expressed as a linear value in watts per metre per kelvin along the perimeter.

On a well detailed installation that linear loss is small. On a badly detailed one it can add more heat loss than the difference between double and triple glazing. The failure is nearly always the same: insulation between the rafters is cut short of the frame, leaving a gap of 20 to 50mm filled with air, plasterboard is fixed over the top, and the finished reveal looks perfect. Around the full perimeter of a 1340 by 980mm window that is over four and a half metres of uninsulated line.

Doing it properly means insulation carried tight to the frame all the way round with no voids, rigid board cut to fit rather than mineral wool stuffed into a gap, the vapour control layer taped to the frame itself rather than trimmed to the plasterboard edge, and continuity maintained between the reveal insulation and the main roof insulation so there is no interruption in the line. Where the rafter depth is too shallow to take the full thickness, insulated plasterboard over the reveal makes up the difference.

The insulation continuity around a reveal is worth more than a glazing upgrade, and it is the one part of the specification a homeowner can never inspect afterwards.

Surface temperature factor, dew point, and mould you can predict in advance

A roof window sitting in the plane of a tiled slope

Mould at the top corners of a rooflight reveal is not bad luck and it is not a fault in the unit. It is arithmetic that can be done before the job starts.

Every junction in a building has a temperature factor, written fRsi, which compares the internal surface temperature at the coldest point of the junction against the difference between inside and outside air. For dwellings the accepted critical value is 0.75. Above that, the surface stays warm enough that indoor air at normal humidity does not reach dew point on it. Below it, condensation forms repeatedly on the same spot, the plaster stays damp, and mould follows within a couple of winters.

Work the numbers for a January morning: 20 degrees inside, zero outside, indoor relative humidity at 60 per cent after a family has showered and cooked. Dew point is around 12 degrees. A junction at a factor of 0.75 holds its coldest surface at 15 degrees, which is safely clear. A junction at 0.55, which is what a 40mm insulation gap at the head of a reveal delivers, sits at 11 degrees and is below dew point every cold morning.

That is why a damp mark in the upper corners of a reveal is a construction finding rather than a weathering one, and why the answer is opening the reveal and reinstating the insulation and vapour layer tight to the frame. Condensation on the glass itself is a different matter and a normal one, covered in the ventilation section below.

  • 20°
  • 12°
  • 15°
  • 40mm

Air leakage at the perimeter, and the draught that is not the glass

Draughts around a rooflight are almost never coming through the glass and rarely through the sash. They come through the perimeter, where the frame meets the roof construction, and through the reveal, where the vapour control layer was cut short or punctured.

Manufactured roof windows are tested for air permeability and the good ones achieve the top class, which is a demanding standard. That class describes the unit as it left the factory. Installed air tightness is entirely down to how the perimeter was sealed: a continuous insulating collar or foam skirt around the frame, an airtightness membrane taped to the frame and lapped into the ceiling vapour layer, and no service penetrations left open. Uncontrolled air movement carries both heat and moisture, and the moisture is the more damaging of the two because it condenses inside the construction where nobody sees it.

Exposure raises the stakes. The Forest of Dean takes driving rain and wind from the south west with real force behind it, and around Coleford, Cinderford and Mitcheldean the pressure difference across a roof on a windy night is much higher than in the shelter of the vale. Higher pressure difference means more air pushed through any gap, so an exposed site loses more heat through an identical leak, and the perimeter sealing and flashing laps are taken further than the minimum for that reason.

Background ventilation without throwing the heat out

Ventilation and insulation look like opposites and are not. A house needs a continuous, small, controlled air exchange to carry away the moisture generated by cooking, washing and drying clothes indoors. Without it, the moisture lands on the coldest surface available, which in a loft room is the glass overhead.

Controlled ventilation is cheap in energy terms because it is small and steady. A trickle vent or a ventilation flap in the head of a roof window, left open, exchanges a modest volume continuously and costs very little heat. Uncontrolled leakage through gaps is expensive because it is driven by wind and stack pressure and is largest exactly when the weather is worst.

Purge ventilation is the other half. Opening a unit fully for a few minutes after a shower clears far more moisture than an hour of trickle, and cools the room surfaces very little because the fabric holds its heat. Where a unit is high above a stairwell and nobody can reach the handle, a rain-sensing electric opener is what turns a theoretical vent into a used one. Where daylight is wanted in a windowless bathroom or landing without adding a full opening, a sun tunnel is often the better answer, since a sealed tube with a diffuser at ceiling level adds very little heat loss.

Water on the room side of the glass on a cold morning is condensation, not a defect. The controls are the vent flap, the purge, and a horizontal cill lining that lets warm air rise up the face of the glass rather than a splayed cill that traps a pocket of still cold air against it.

Conservation rooflights on Cotswold stone slate: what the slim steel frame costs

Gloucestershire is where thermal specification and conservation specification collide, and the honest position is that the two cannot both be optimised.

A conservation rooflight exists because a Cotswold roof is built from stone slate 20 to 30mm thick, graded in diminishing courses up the slope, at a roof loading well over 100 kilograms per square metre. Nothing with a chunky modern frame sits flush in that. The answer is a cast or pressed steel frame, slim in section, with a single central glazing bar, set nearly level with the slate. Painswick, Bibury, Northleach, Chipping Campden and the wolds villages between them are full of roofs where that is the only unit a conservation officer will accept.

Steel conducts heat at around 50 W/mK, roughly four hundred times better than the timber in a manufactured roof window. The frame is slim, so there is nowhere to put an insulating break, and the central glazing bar adds a second conductive line straight across the middle of the glass. A conservation unit with a good double-glazed panel typically lands at a whole-unit value of 1.6 to 2.0 where a timber roof window with the same glass would be 1.2. Some manufacturers now offer a thermally improved version with a polyamide break behind the steel face, or a slim krypton-filled triple panel in the same rebate, and where the officer will accept it that is the specification to push for.

Two things put the trade in proportion. First, these are small units by modern standards, often 600 by 900mm or less, because that is what the roof and the officer will take, so the total area of poorer glass is limited. Second, the roof around it is frequently uninsulated, or insulated to a 1970s standard, and often has lime mortar torching instead of any underlay. In that context the rooflight is not the weakest element in the roof by a wide margin. The detail of the product and the consent route is on the conservation rooflight installation page.

Daylight from above falling across an interior wall
Daylight from above falling across an interior wall

Near-horizontal glass behind a Cheltenham parapet

Central Cheltenham’s Regency terraces at Lansdown, Montpellier, Pittville and along the Bath Road are mansard-roofed: a steep lower slope visible from the pavement, and a shallow upper slope behind a parapet that nobody on the street can see. The shallow slope is where a rooflight can realistically go, and it is thermally the hardest position in the county.

At five to fifteen degrees the glass is close enough to horizontal that cavity convection is at its worst, so the installed U-value sits well above the vertically declared figure. The same geometry means near-maximum solar collection in June and very little in December. And a pitch that shallow is below the minimum most manufactured roof windows are rated for, so the unit becomes a kerb-mounted rooflight on a small upstand, which brings its own thermal question: a timber kerb insulated only on the inside face becomes a cold ring of timber and plasterboard around the glass. The kerb is insulated on the outside face, under the waterproofing, so the whole assembly stays inside the warm envelope.

The specification that suits this position is a triple-glazed or slim-cavity unit to fight the convection, solar control on the outer pane because summer gain is the dominant load, and a properly insulated kerb. Where the flat area behind the parapet is also a terrace, a walk-on rooflight changes the frame geometry again and the thermal detailing has to be worked out around a much heavier build-up.

Interwar hips and the south-west facing rear slope

Longlevens, Hucclecote, Tuffley, Warden Hill and Charlton Kings are largely interwar and post-war semis with hipped roofs at 30 to 35 degrees under concrete interlocking tiles. Structurally these are the friendliest roofs in the county: cut roofs with purlins and struts, where a rafter can be trimmed without a designed member.

Thermally they present a specific problem. A great many of these houses were built on estate layouts where the rear elevation faces somewhere between south and west, and a 30 degree slope facing south-west is very close to the worst orientation and pitch combination available at this latitude. It takes the June sun almost square-on at midday, then keeps taking it through the afternoon as the sun swings west and drops. A hip also narrows towards the corner, so the usable rectangle is smaller than the roof looks, which means the glass tends to be placed high on the slope where it is most exposed and hardest to shade from inside.

The specification that follows is solar control glass as a default rather than an option, and an external awning specified at the same time as the unit. Two smaller units in adjacent rafter bays also help here for a reason that is nothing to do with structure: two openings spread the daylight more evenly across the room than one large one, so the same lighting result is achieved with less total glazed area and therefore less solar gain.

Rafter depth on the trussed estates, and where 300mm of insulation has to go

A flush glazed rooflight set into a flat roof

Quedgeley, Abbeydale, Brockworth, Bishops Cleeve, Ashchurch and Yate are trussed rafter construction, and the thermal question there is different from anywhere else because these roofs were built to a modern insulation standard and the insulation is usually in the ceiling rather than at the rafter line.

That matters for a rooflight in two ways. If the loft stays a cold loft and the rooflight is going into a room below, the opening is a sun tunnel rather than a window, and the thermal detail is about sealing and insulating the tube where it crosses the cold space. If the loft is being converted, the insulation line moves from the ceiling to the rafters, and a trussed rafter is typically only 97 or 120mm deep. Current standards want considerably more than that, so the build-up becomes insulation between the rafters, a counter batten or insulated plasterboard below them, and a maintained 25mm ventilation gap above.

The rooflight reveal has to be detailed into that build-up rather than treated as a hole through it. The insulation depth at the head of the opening is where it goes wrong, because that is where the trimmer sits and where the temptation is to stop the insulation at the timber. The trussed roof also decides the size: between two trusses at 600mm centres there is around 550 to 570mm of clear width, so narrow units at 550mm wide are what fits, and two of them in adjacent bays give more glass and better light distribution than one wide opening carried on a designed beam.

  • 120mm
  • 25mm
  • 600mm
  • 570mm

Cold air draining down the Stroud valleys after dark

The Stroud valleys have a microclimate that shows up in condensation rather than in heating bills. On a clear, still night, air in contact with the hillsides cools, becomes denser, and drains downhill into the valley bottoms, where it pools. The result is that Chalford bottom, the Frome valley floor and the lower parts of Brimscombe can be several degrees colder overnight than Rodborough or Minchinhampton a couple of hundred metres above them, and frost forms there when the ridge stays clear.

For a rooflight, every one of those extra cold degrees on the outer pane pushes the inner surface closer to dew point. A unit that never condenses on a hillside above the valley will run wet on the same house type at the bottom of it. So in those addresses the useful moves are a warm-edge spacer as a minimum, a triple unit where the budget allows, and particular attention to the temperature factor at the reveal junction, because a marginal detail that copes at zero degrees will not cope at minus four.

The access side of these valleys is a separate matter and a real one. Terraces step up the hillside, lanes are shared, and scaffold is often hand-carried, so the same unit takes longer to install in Chalford than in Quedgeley. That is looked at properly at survey so the figure holds.

Heat pumps, lower flow temperatures, and why the reveal matters more now

Air source heat pumps are going into Gloucestershire houses steadily, and they change what a rooflight has to do. A gas boiler runs a radiator circuit at 70 to 80 degrees. A heat pump runs efficiently at 35 to 45. The heat delivered per hour can be the same, from larger emitters at a lower surface temperature, but the character of it changes.

Two consequences follow for overhead glazing. The first is that a low-temperature radiator produces a much weaker convective plume, so the warm air wash rising up the face of the glass is gentler. That plume is what keeps a rooflight’s inner surface above dew point in a well arranged room, so with a heat pump the reveal geometry matters more: a horizontal cill lining that lets the plume reach the glass, rather than a splayed cill that deflects it into the room, stops being a nicety.

The second is that a low-temperature system has much less capacity to overwhelm a cold spot. A boiler-fed room recovers quickly from a draught or a cold bridge because it can dump heat in fast. A heat pump system is sized to hold a steady state, so any fabric weakness shows up as a room that never quite gets there rather than one that takes a while. That puts the whole-unit U-value, the perimeter air tightness and the reveal insulation continuity ahead of everything else on the specification list for a house on a heat pump, or a house likely to be on one within the lifetime of the glazing.

Part L, the limiting standard, and what the notification records

Replacing a rooflight or putting a new one in is notifiable work, and the conservation of fuel and power part of the regulations sets a limiting standard the unit has to meet. Current guidance sets that limit at 1.4 W/m2K for a replacement roof window, whole unit, and quotes rooflights at 2.2 W/m2K measured in the vertical plane, which is the convention described earlier on this page.

Any current manufactured unit clears both figures comfortably, so the limiting standard is rarely the constraint. What is worth understanding is what else the same part of the regulations covers, because the glass is the smaller part of it:

  • Insulation continuity. The requirement covers avoiding excessive thermal bridging at junctions, which is the reveal detail rather than the unit.
  • Air tightness at the perimeter. Reasonable provision includes sealing the junction between the new frame and the existing construction.
  • Solar gain control. Where a significant area of glazing is being added, limiting summer overheating is part of the same reasonable provision.
  • The declared figures. The unit’s certified U-value and g-value are recorded with the application, which is why the manufacturer’s data sheet is kept rather than binned with the packaging.

The notification is submitted as part of the job, the inspections are booked, and the completion certificate is issued in the homeowner’s name. It is the document a buyer’s solicitor asks for, and it names the specification that was installed, which is the only durable record of what the glass actually is once the labels come off.

EPCs, daylight, and the honest arithmetic on running costs

Homeowners often ask whether new rooflights will move an EPC band. The straight answer is that they seldom do on their own. A reduced-data energy assessment is dominated by the heating system, the wall construction, the loft or rafter insulation and the fuel, and glazing enters as a type and an age band rather than as the specific U-value on the certificate. Replacing one or two units in a roof is a small change to a small term in a large calculation. Convert a loft, insulate it to current standards, and fit good rooflights as part of that, and the band moves, though the rooflights are the smallest contributor to the move.

The genuine energy case for a rooflight is daylight rather than heat. A horizontal or shallow opening sees a much larger area of sky than a vertical window of the same size, which is why the accepted rule of thumb is that a rooflight delivers roughly two to three times the daylight of an equivalent area of wall glazing. In a Gloucester rear-addition kitchen or a windowless landing, that is the difference between electric light on all day and electric light on at dusk.

Being straight about the balance: a rooflight is a hole in the insulated envelope and a well specified one still loses heat faster than the roof it replaced. The winter heating cost goes up slightly. The lighting cost goes down, the room becomes usable at times it previously was not, and on a south-facing slope there is some useful winter gain on bright days. Anyone selling a rooflight purely as an energy-saving measure is overselling it. Specified properly it is close to thermally neutral and a substantial gain in how a house works, which is the honest claim.

Specifying a unit: what gets recorded at survey for thermal purposes

The thermal decisions are made from a specific list of measurements taken on the day, alongside the structural ones.

  • Orientation of the slope, taken off a compass, and the pitch off a digital level, because those two together set the solar load.
  • Overshading from neighbouring buildings, a hillside or mature trees, which can remove the summer problem entirely on a Stroud valley site and never on an open Quedgeley estate.
  • The room below: what it is used for, at what hours, and whether it is heated to a steady temperature or intermittently.
  • Existing insulation: where the line runs, what thickness, what type, and whether a ventilation gap survives above it.
  • Rafter or truss depth, which decides how much insulation can be carried around the reveal without an insulated board build-up.
  • Heating in the room: whether there is an emitter under the proposed position, its type, and the system flow temperature.
  • Humidity sources: a bathroom, a kitchen, or clothes dried indoors, all of which raise the dew point the reveal detail has to beat.
  • Whether other units on the same roof are the same age, since matching build-ups across an elevation is worth planning as one visit.

From that list comes a glass build-up, a frame type, a shading recommendation and a reveal detail, written down rather than assumed. Where an existing unit is being taken out, the same survey records what the old specification was, which is usually readable from the size code stamped on the sash and covered further on the skylight replacement page.

What moves the price of a higher specification

No figures are published on this site, because a triple-glazed conservation unit into diminishing courses of stone slate on a Painswick cottage with hand-carried scaffold, and a solar control double unit between two trusses on a Quedgeley semi with a driveway to park on, are not the same job at any price.

What actually moves it on the thermal side:

  • Double against triple glazing, and whether the cavity gas is argon or krypton.
  • Whether solar control is on the outer pane, which is a coating cost rather than a labour cost.
  • Laminated inner panes, which are required over habitable space and a bath in any case, so rarely an option.
  • External shading, much cheaper fitted while the scaffold is up than as a return visit.
  • Frame type, and whether a thermally improved conservation profile is available in the size the officer will accept.
  • How far the reveal has to be built out to carry full insulation depth, and whether insulated plasterboard is needed.
  • Whether an electric opener and rain sensor are wanted, which brings mains wiring and its own sign-off.
  • How many units, and whether one scaffold and one notification cover them all.

The process is two figures in this order. An indicative range comes back by email from photographs of the roof outside, the room inside, the covering, a rough size and the address. Then, after a survey, a fixed price, itemised so it is clear what is unit, what is glass upgrade, what is labour, what is scaffold and what is Building Control. The costs page sets out how that works, the areas pages cover the thirty miles by road around Gloucester, and the written guides go further into individual questions. To start, email info@severnskylightsgloucester.co.uk with the orientation of the slope if you know it, because on a Gloucestershire roof that one fact narrows the glass specification more than anything else you can tell us.